Chamber volume
cc
in³
Swept volume
cc
in³
V1 - Start volume
1500
Chamber volume + swept volume
cc
91.5
in³
P1 - Pre-charge
MPa
psi
T1 - Ambient
°C
°F
End press. (slow)
30
The end pressure if the compression is slow,
allowing heat to dissipate. Boyle's law.
MPa
4500
psi
ΔT - Temp rise
15
Temperature rise due to adiabatic compression.
°C
30
°F
P2 - End pressure
30
End pressure, taking account of the temperature rise.
MPa
4500
psi
Force Ratio
1.8
Force at end of stroke (compressed), relative to start
to 1
Energy
6000
J